Swiper demo

Stainless steel safety switch ZCode

  Lagerbestand gering. Lieferzeit auf Anfrage.
Artikelnummer:  66107-940147

The Zander stainless steel safety switches are specially designed for the chemical, pharmaceutical and food industries.

Due to high temperature resistance (105°C), high hygiene insensitivity and also high chemical resistance, the stainless steel safety switches, the stainless steel pull-rope switch and the stainless steel magnetic locking device are ideally suited for the requirements of the process and food industry (also for CIP & SIP suitable for cleaning).

All safety switches in the ZCode series work contact-free using a coded magnet system with a large switching distance and large tolerance to offset on the protective door.Activation can only take place with the actuator included in the scope of delivery.The switching status is indicated by an LED.

All ZCode stainless steel safety switches meet the requirements of ISO 13849 (PLe) and 14119 (Type 4).


Type safety contacts/outputs (closer) Auxiliary contacts / outputs (NC contacts) temp.-Area Width in mm
ZCode-LCE 2 1 -25°C to +105°C 88x25x13mm
ZCode-TCE 2 1 -25°C to +105°C 36x26x13mm
ZCode-MC 2 1 -25°C to +105°C 50x25x13mm
ZCode MCF 2 1 -25°C to +105°C 50x25x13mm
ZCode-CCE 2 1 -25°C to +105°C 85x20x17mm
ZCode-CCEF 2 1 -25°C to +105°C 85x20x17mm
ZCode-RCE 2 1 -25°C to +105°C D 30 x L 60mm
ZCode-LRE 2 1 -25°C to +80°C
(+105 °C briefly)
88x25x18mm

Manufacturer: Hermann ZANDER GmbH & Co.KG
ZCode-LCE ZCode-TCE ZCode-MC ZCode MCF ZCode-CCE
Possible uses Can also be used on poorly aligned protective doors, sliding protective grilles or protective covers Ideal sensor for use where space is limited Areas with high hygiene requirements, food industry, chemical industry Areas with high hygiene requirements, food industry, chemical industry Can also be used on poorly aligned protective doors, sliding protective grilles or protective covers.
Certified to ISO 13849-1; EN 62061, EN ISO 14119; EN60204-1; EN60947-5-3; according to UL508 ISO 13849-1; EN 62061, EN ISO 14119; EN60204-1; EN60947-5-3; according to UL508 ISO 13849-1; EN 62061, EN ISO 14119; EN60204-1; EN60947-5-3; according to UL508 ISO 13849-1; EN 62061, EN ISO 14119; EN60204-1; EN60947-5-3; according to UL508 ISO 13849-1; EN 62061, EN ISO 14119; EN60204-1; EN60947-5-3; according to UL508
Approvals CE, TUV, UL CE, TUV, UL CE, TUV, UL CE, TUV, UL CE, TUV, UL
Power supply DC 24V; +/- 15%, max.50mA DC 24V; +/- 15%, max.50mA DC 24V; +/- 15%, max.50mA DC 24V; +/- 15%, max.50mA DC 24V; +/- 15%, max.50mA
Number of semiconductor outputs 2 contactless safety outputs, 1 signaling output 2 contactless safety outputs, 1 signaling output 2 contactless safety outputs, 1 signaling output 2 contactless safety outputs, 1 signaling output 2 contactless safety outputs, 1 signaling output
Signal contact n/a n/a n/a n/a n/a
Switching capacity (safe & signaling outputs) DC 24V; Max.200mA; short-circuit proof DC 24V; Max.200mA; short-circuit proof DC 24V; Max.200mA; short-circuit proof DC 24V; Max.200mA; short-circuit proof DC 24V; Max.200mA; short-circuit proof
minimum load current DC 24V; 1mA DC 24V; 1mA DC 24V; 1mA DC 24V; 1mA DC 24V; 1mA
Recommended switching distance, maximum. 5mm, 10mm close / 22mm open 5mm, 8mm close / 12mm open 5mm, 10mm close / 22mm open 5mm, 10mm close / 22mm open 5mm, 10mm close / 22mm open
Housing material 316 stainless steel 316 stainless steel mirror polished finish stainless steel 316 stainless steel 316 stainless steel
degree of protection IP67, IP69K (with M12 connector IP67) IP67, IP69K (with M12 connector IP67) IP67, IP69K (with M12 connector IP67) IP67, IP69K (with M12 connector IP67) IP67, IP69K (with M12 connector IP67)
Temperature range -25°C to +105°C -25°C to +105°C -25°C to +105°C -25°C to +105°C -25°C to +105°C
PL; cat; SILCL (EN ISO 13849-1; EN /IEC 62061) PL e; cat4 PL e; cat4 PL e; cat4 PL e; cat4 PL e; cat4
Vibration, shock resistance 10-55Hz / 1mm, 1ms / 30g 10-55Hz / 1mm, 1ms / 30g 10-55Hz / 1mm, 1ms / 30g 10-55Hz / 1mm, 1ms / 30g 10-55Hz / 1mm, 1ms / 30g
weight, dimension 200g, 88x25x13mm 200g, 36x26x13mm 300g, 50x25x13mm 300g, 50x25x13mm 200g, 85x20x17mm

ZCode-CCEF ZCode-RCE ZCode-LRE RFID
Applications Can also be used on poorly aligned protective doors, sliding protective grilles or protective covers. Protective doors, sliding protective grilles or protective covers. High requirements for protection against manipulation, use also on poorly aligned protective doors, sliding protective grilles or protective covers
Certified to ISO 13849-1; EN 62061, EN ISO 14119; EN60204-1; EN60947-5-3; according to UL508 ISO 13849-1; EN ISO 14119; EN60204-1; EN60947-5-3; according to UL508; CSA-C22.2 no.14 ISO 13849-1; EN 62061, EN ISO 14119; EN60204-1; EN 60947-5-3
Approvals CE, TUV, UL CE, TUV, UL CE, TÜV
Power supply DC 24V; +/- 15%, max.50mA DC 24V; +/- 10% 2 contactless safety outputs, 1 signaling output
Number of semiconductor outputs 2 contactless safety outputs, 1 signaling output 2 contactless safety outputs, 1 signaling output n/a
Signal contact n/a n/a 1
Switching capacity (safe & signaling outputs) DC 24V; Max.200mA; short-circuit proof DC 24V; Max.500mA; short-circuit proof DC 24V; Max.200mA; short-circuit proof
Minimum load current DC 24V; 1mA DC 10V; 1mA DC 24V; +/- 10%
Recommended sensing range, maximum. 5mm, 10mm close / 22mm open 5mm, 10mm close / 22mm open 5mm, 10mm close / 20mm open
Housing material 316 stainless steel 316 stainless steel 316 stainless steel
degree of protection IP67, IP69K (with M12 connector IP67) IP67, IP69K (with M12 connector IP67) IP67, IP69K (with M12 connector IP67)
Temperature range -25 °C to +105 °C -25 °C to +105 °C -25°C to +80°C
PL; cat; SILCL (EN ISO 13849-1; EN /IEC 62061) PL e; cat4 PL e; cat4 PL e; cat4
Vibration, shock resistance 10-55Hz/1mm, 1ms/30g 10-55Hz/1mm, 11ms/30g 10-55Hz/1mm, 1ms/30g
Weight, dimension 300g, 83x20.6x17mm 110g, 30x60mm (switch: 15mm) 200g, 88x25x18mm

Please ask us for the data sheet.